Estriol Kit CLIA

Kit ELISA Différentes espèces Estriol, test Chemiluminescent pour la quantification de Différentes espèces Estriol.
N° du produit ABIN5653985

Aperçu rapide pour Estriol Kit CLIA (ABIN5653985)

Antigène

Tous les produits Estriol
Estriol

Reactivité

Différentes espèces

Méthode de détection

Chemiluminescent

Type de méthode

Competition ELISA

Gamme de detection

781.25 pg/mL - 200000 pg/mL

Application

ELISA

Type d'échantillon

Plasma, Serum
  • Seuil minimal de détection

    781.25 pg/mL

    Analytical Method

    Quantitative

    Specificité

    This assay has high sensitivity and excellent specificity for detection of Estriol (E3). No significant cross-reactivity or interference between Estriol (E3) and analogues was observed.

    Sensibilité

    262.3 pg/mL
  • Commentaires

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    Durée du test

    2 h

    Plaque

    Pre-coated

    Protocole

    The microplate provided in this kit has been pre-coated with a monoclonal antibody specific to Estriol (E3). A competitive inhibition reaction is launched between biotin labeled Estriol (E3) and unlabeled Estriol (E3) (Standards or samples) with the pre-coated antibody specific to Estriol (E3). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Estriol (E3) in the sample. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is reverse proportional to the Estriol (E3) level in the sample or standard.

    Précision du teste

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Estriol (E3) were tested 20 times on one plate, respectively
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Estriol (E3) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Restrictions

    For Research Use only
  • Conseil sur la manipulation

    Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.

    Stock

    4 °C,-20 °C

    Stockage commentaire

    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.

    Date de péremption

    4-8 months
  • Antigène Tous les produits Estriol

    Estriol

    Classe de substances

    Hormone

    Sujet

    Gene Name: Estriol

    Gene Aliases: oestriol